LCAOS (258868)
https://cordis.europa.eu/project/id/258868
FP7 (2007-2013)
A Nanoscale Artificial Nose to easily detect Volatile Biomarkers at Early stages of Lung Cancer and Related Genetic Mutations
Tools for the identification and the detection of biomarkers in clinical samples and patients. FP7-HEALTH-2010-two-stage. (HEALTH.2010.1.2-1)
medical biotechnology · lung cancer · nanotechnology · pattern recognition · metalloids
2011-04-01 Start Date (YY-MM-DD)
2015-03-31 End Date (YY-MM-DD)
€ 5,405,173 Total Cost
Description
The LCAOS project will develop and test a new diagnostic tool, able to detect: (i) the presence of lung cancer (LC), and (ii) an increased risk of a patient developing LC in the future. Diagnostic tests currently available are unsuitable for widespread screening because they are costly, occasionally miss tumours, are not time-efficient, nor free of complications. LCAOS will overcome these problems by using an approach based on volatile biomarkers emitted from cell membranes. A multidisciplinary effort, incorporating nanotechnology, biomedical engineering, medical oncology, and computation strategies, will develop a highly-sensitive, inexpensive, and fast-response, non-invasive, artificial nose (known as, NaNose), building on the coordinator’s earlier success in this area. The NaNose will be able to detect pre-neoplastic volatile biomarkers that indicate an increased genetic risk of LC, and the presence of LC. It has already been established that these biomarkers can be detected either directly from the headspace of the cancer cells or via exhaled breath. LCAOS will: (i) develop arrays of chemically-sensitive field effect transistors (FETs) of non-oxidized, molecule-terminated silicon nanowires (Si NWs); (ii) test the ability of these devices to sense volatile LC biomarkers from in-vitro tissue, and exhaled human breath; (iii) study the signal transduction mechanism of the volatile biomarkers, using pattern recognition; (iv) improve systems to enable the NaNose to distinguish the targeted biomarkers from environmental clutter, using methylation, expression profiling, and genome-wide sequencing; and (v) perform clinical-related studies to assess LC conditions in actual patients & tissues, and in the presence of real-world confounding signals. Validation will be carried out by clinician partners and professional mathematicians and computer scientists. Resources will also be allocated to ensure the commercial potential of the sensor device layout.
Complicit Organisations
2 Israeli organisations participate in LCAOS.Country | Organisation (ID) | VAT Number | Role | Activity Type | Total Cost | EC Contribution | Net EC Contribution |
---|---|---|---|---|---|---|---|
Germany | JLM INNOVATION GMBH (971016464) | DE274114085 | participant | PRC | € 0 | € 301,435 | € 0 |
Austria | Ionimed Analytik GmbH (984140273) | nan | participant | PRC | € 0 | € 0 | € 0 |
Netherlands | MICRONIT HOLDING BV (987731989) | NL809482952B01 | participant | PRC | € 0 | € 181,185 | € 0 |
Spain | UNIVERSIDAD COMPLUTENSE DE MADRID (999874546) | ESQ2818014I | participant | HES | € 0 | € 412,607 | € 0 |
Israel | TEL AVIV UNIVERSITY (999901609) | IL589931187 | participant | HES | € 0 | € 473,367 | € 0 |
United Kingdom | THE UNIVERSITY OF LIVERPOOL (999980567) | GB673598875 | participant | HES | € 0 | € 654,457 | € 0 |
Israel | TECHNION - ISRAEL INSTITUTE OF TECHNOLOGY (999907720) | IL557585585 | coordinator | HES | € 0 | € 1,211,702 | € 0 |
Germany | MAX-PLANCK-GESELLSCHAFT ZUR FORDERUNG DER WISSENSCHAFTEN EV (999990267) | DE129517720 | participant | REC | € 0 | € 577,099 | € 0 |
Austria | IONICON ANALYTIK GMBH (999692671) | ATU45012203 | participant | PRC | € 0 | € 328,320 | € 0 |